Technician’s Handbook
54
Interpreting the Main Control Card
Power-Up Error Codes
The error codes listed in Table 3 may appear on the Main Control Card
numeric display during startup.
NOTE: 1. A normal running system may show other codes (card diagnostics or errors).
However, during start-up, only the codes in this table are possible. Any other
code shown during start-up indicates a faulty Main Control Card.
2. Codes possible AFTER start-up include card diagnostics codes (last card lo-
cation tested - top number indicates bay number, bottom number indicates
card slot number). Maintenance logs give results of test, pass or fail with
cause.
Table 3: Main Control Card Error Code Summary
Error
Code
Likely Cause(s)
(blank) • Faulty power system.
• Faulty Main Control Card.
0 • Faulty Main Control Card.
E.
8
• MOSS password was not purchased, a purchased option is
not enabled, an enabled option is not purchased, the system
password does not match, or the system id does not match.
• Faulty System ID module.
C • Faulty Flash memory or Main Control Card - This code shows
for approximately 15 seconds during a proper power-up
sequence. If the code remains, then a problem exists.
-
-
• Nothing - indicates successful software download. This
display may be immediately changed to display post-boot-up
codes (see note 1).
Commentaires sur ces manuels